Name: Fuses
Display Field: OBJECTID
Type: Feature Layer
Geometry Type: esriGeometryPoint
Is View: true
Is Updatable View: true
Source Schema Changes Allowed: true
Sources
Description:
Copyright Text:
Min. Scale: 1500
Max. Scale: 0
Default Visibility: false
Max Record Count: 2000
Supported query Formats: JSON, geoJSON, PBF
Use Standardized Queries: True
Extent:
XMin: 3036372.35804759
YMin: 590523.563575298
XMax: 3078489.84487082
YMax: 653667.917746097
Spatial Reference: 102682 (3452)
Drawing Info:
{"renderer":{"type":"uniqueValue","field1":"SUBTYPECD","uniqueValueGroups":[{"heading":"Subtype","classes":[{"label":"Line Fuse","description":"Line Fuse","symbol":{"type":"esriPMS","url":"d545a9c0325d5473baafdcf65a8ecafe","imageData":"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","contentType":"image/png","width":11,"height":11,"angle":0,"xoffset":0,"yoffset":0},"values":[["1"]]},{"label":"UG Fuse","description":"UG Fuse","symbol":{"type":"esriPMS","url":"1a59ad1fdf91a00638b3b58ae19cf929","imageData":"iVBORw0KGgoAAAANSUhEUgAAAAsAAAALCAYAAACprHcmAAAACXBIWXMAAA7EAAAOxAGVKw4bAAAAvUlEQVQYlZ2QOwrCABBE3yapRIifQsTCxs7CTiWJR7D0LF7DM3gSIcYPioi1YmMjiKCVQZMVxEYSEJ1qd3kMM2vxg6z/4aVmeFDjTgGTA45s0+GZlriRw5MNgfaJqeBrkY7Mk7BSwZPVa74wwMbGoEegJ1zZfcIPInztYpJHMV+3mBFKNuksVDEIcWT40cPXRlrBM0qTQMvAGlfWjLWOxT4Ju0yYEGISEtFiqgbKkbZcU2JIDCze2+b7n7/oCXpGORvIgme3AAAAAElFTkSuQmCC","contentType":"image/png","width":8,"height":8,"angle":0,"xoffset":0,"yoffset":0},"values":[["2"]]}]}],"uniqueValueInfos":[{"symbol":{"type":"esriPMS","url":"d545a9c0325d5473baafdcf65a8ecafe","imageData":"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","contentType":"image/png","width":11,"height":11,"angle":0,"xoffset":0,"yoffset":0},"value":"1","label":"Line Fuse"},{"symbol":{"type":"esriPMS","url":"1a59ad1fdf91a00638b3b58ae19cf929","imageData":"iVBORw0KGgoAAAANSUhEUgAAAAsAAAALCAYAAACprHcmAAAACXBIWXMAAA7EAAAOxAGVKw4bAAAAvUlEQVQYlZ2QOwrCABBE3yapRIifQsTCxs7CTiWJR7D0LF7DM3gSIcYPioi1YmMjiKCVQZMVxEYSEJ1qd3kMM2vxg6z/4aVmeFDjTgGTA45s0+GZlriRw5MNgfaJqeBrkY7Mk7BSwZPVa74wwMbGoEegJ1zZfcIPInztYpJHMV+3mBFKNuksVDEIcWT40cPXRlrBM0qTQMvAGlfWjLWOxT4Ju0yYEGISEtFiqgbKkbZcU2JIDCze2+b7n7/oCXpGORvIgme3AAAAAElFTkSuQmCC","contentType":"image/png","width":8,"height":8,"angle":0,"xoffset":0,"yoffset":0},"value":"2","label":"UG Fuse"}],"fieldDelimiter":",","authoringInfo":{"colorRamp":{"type":"multipart","colorRamps":[{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,231,207,255],"toColor":[252,231,207,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[197,182,252,255],"toColor":[197,182,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[179,252,190,255],"toColor":[179,252,190,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[179,244,252,255],"toColor":[179,244,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,194,223,255],"toColor":[252,194,223,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[242,252,182,255],"toColor":[242,252,182,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[182,209,252,255],"toColor":[182,209,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[210,252,223,255],"toColor":[210,252,223,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,194,179,255],"toColor":[252,194,179,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[250,184,252,255],"toColor":[250,184,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[239,215,252,255],"toColor":[239,215,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[215,235,252,255],"toColor":[215,235,252,255]},{"type":"algorithmic","algorithm":"esriCIELabAlgorithm","fromColor":[252,230,179,255],"toColor":[252,230,179,255]}]}}},"scaleSymbols":true,"transparency":0,"labelingInfo":null}
HasZ: false
HasM: false
Has Attachments: false
Has Geometry Properties: false
HTML Popup Type: esriServerHTMLPopupTypeNone
Object ID Field: OBJECTID
Unique ID Field:
IsSystemMaintained : True
Global ID Field: GlobalID
Type ID Field: SUBTYPECD
Fields:
- OBJECTID (type: esriFieldTypeOID, alias: OBJECTID, SQL Type: sqlTypeOther, length: 0, nullable: false, editable: false)
- ANCILLARYROLE (type: esriFieldTypeSmallInteger, alias: ANCILLARYROLE, SQL Type: sqlTypeOther, nullable: true, editable: true)
- ENABLED (type: esriFieldTypeSmallInteger, alias: Enabled, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [0: False], [1: True])
- CREATIONUSER (type: esriFieldTypeString, alias: Creation User, SQL Type: sqlTypeOther, length: 50, nullable: true, editable: true)
- DATECREATED (type: esriFieldTypeDate, alias: Date Created, SQL Type: sqlTypeOther, length: 8, nullable: true, editable: true)
- DATEMODIFIED (type: esriFieldTypeDate, alias: Date Modified, SQL Type: sqlTypeOther, length: 8, nullable: true, editable: true)
- LASTUSER (type: esriFieldTypeString, alias: Last User, SQL Type: sqlTypeOther, length: 50, nullable: true, editable: true)
- SUBTYPECD (type: esriFieldTypeInteger, alias: Subtype, SQL Type: sqlTypeOther, nullable: true, editable: true)
- FACILITYID (type: esriFieldTypeString, alias: Facility ID, SQL Type: sqlTypeOther, length: 20, nullable: true, editable: true)
- FEEDERID (type: esriFieldTypeString, alias: Feeder ID, SQL Type: sqlTypeOther, length: 20, nullable: true, editable: true)
- FEEDERID2 (type: esriFieldTypeString, alias: Feeder ID 2, SQL Type: sqlTypeOther, length: 20, nullable: true, editable: true)
- OPERATIONVOLTAGE (type: esriFieldTypeInteger, alias: Operating Voltage, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [120: 4.16 kV Grounded Y], [160: 7.2 kV Grounded Y], [210: 12.5 kV Grounded Y], ... 9 more ...)
- COMMENTS (type: esriFieldTypeString, alias: COMMENTS, SQL Type: sqlTypeOther, length: 100, nullable: true, editable: true)
- WORKORDERID (type: esriFieldTypeString, alias: Work Order ID, SQL Type: sqlTypeOther, length: 20, nullable: true, editable: true)
- INSTALLATIONDATE (type: esriFieldTypeDate, alias: Installation Date, SQL Type: sqlTypeOther, length: 8, nullable: true, editable: true)
- FEEDERINFO (type: esriFieldTypeInteger, alias: Feeder Information, SQL Type: sqlTypeOther, nullable: true, editable: true)
- SYMBOLROTATION (type: esriFieldTypeDouble, alias: SYMBOLROTATION, SQL Type: sqlTypeOther, nullable: true, editable: true)
- MAXCONTINUOUSCURRENT (type: esriFieldTypeDouble, alias: Maximum Continuous Current, SQL Type: sqlTypeOther, nullable: true, editable: true)
- MAXINTERRUPTINGCURRENT (type: esriFieldTypeDouble, alias: Maximum Interrupting Current, SQL Type: sqlTypeOther, nullable: true, editable: true)
- MAXIMUMOPERATINGVOLTAGE (type: esriFieldTypeInteger, alias: Maximum Operating Voltage, SQL Type: sqlTypeOther, nullable: true, editable: true)
- NORMALPOSITION_A (type: esriFieldTypeInteger, alias: Normal Position - A, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [1: Closed], [0: Open], [2: Not Applicable])
- NORMALPOSITION_B (type: esriFieldTypeInteger, alias: Normal Position - B, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [1: Closed], [0: Open], [2: Not Applicable])
- NORMALPOSITION_C (type: esriFieldTypeInteger, alias: Normal Position - C, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [1: Closed], [0: Open], [2: Not Applicable])
- LABELTEXT (type: esriFieldTypeString, alias: Label Text, SQL Type: sqlTypeOther, length: 50, nullable: true, editable: true)
- PHASEDESIGNATION (type: esriFieldTypeInteger, alias: Phase Designation, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [4: A], [6: AB], [5: AC], ... 4 more ...)
- NOMINALVOLTAGE (type: esriFieldTypeInteger, alias: Nominal Voltage, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [100: 4 kV], [190: 8 kV], [300: 15 kV], ... 4 more ...)
- MMELECTRICTRACEWEIGHT (type: esriFieldTypeInteger, alias: MMELECTRICTRACEWEIGHT, SQL Type: sqlTypeOther, nullable: true, editable: true)
- SUPPORTSTRUCTUREOBJECTID (type: esriFieldTypeInteger, alias: SUPPORTSTRUCTUREOBJECTID, SQL Type: sqlTypeOther, nullable: true, editable: true)
- OLDOID (type: esriFieldTypeInteger, alias: OLDOID, SQL Type: sqlTypeOther, nullable: true, editable: true)
- ARCFMTAG (type: esriFieldTypeString, alias: Old ArcFM Tag, SQL Type: sqlTypeOther, length: 50, nullable: true, editable: true)
- TAPNUMBER (type: esriFieldTypeString, alias: Tap Number, SQL Type: sqlTypeOther, length: 50, nullable: true, editable: true)
- TEMPFUSESIZE (type: esriFieldTypeInteger, alias: Temp Fues Size, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [10: 10 A], [15: 15 A], [20: 20 A], ... 13 more ...)
- SDEOID (type: esriFieldTypeInteger, alias: SDEOID, SQL Type: sqlTypeOther, nullable: true, editable: true)
- SAVESUPOID (type: esriFieldTypeInteger, alias: Save Sup OID, SQL Type: sqlTypeOther, nullable: true, editable: true)
- FEEDTAPCALC (type: esriFieldTypeString, alias: Feed Tap Calc, SQL Type: sqlTypeOther, length: 50, nullable: true, editable: true)
- PHASE (type: esriFieldTypeString, alias: PHASE, SQL Type: sqlTypeOther, length: 3, nullable: true, editable: true)
- LOCATION (type: esriFieldTypeString, alias: LOCATION, SQL Type: sqlTypeOther, length: 50, nullable: true, editable: true)
- WARRANTYDATE (type: esriFieldTypeDate, alias: WARRANTYDATE, SQL Type: sqlTypeOther, length: 8, nullable: true, editable: true)
- LEGACYID (type: esriFieldTypeString, alias: LEGACYID, SQL Type: sqlTypeOther, length: 20, nullable: true, editable: true)
- LINKTYPE (type: esriFieldTypeString, alias: LINKTYPE, SQL Type: sqlTypeOther, length: 50, nullable: true, editable: true, Coded Values: [H: H Link], [K: K Link], [N: N Link], ... 4 more ...)
- LINKRATING (type: esriFieldTypeInteger, alias: Link Rating, SQL Type: sqlTypeOther, nullable: true, editable: true, Coded Values: [10: 10 A], [15: 15 A], [20: 20 A], ... 13 more ...)
- OMSCREWZONES (type: esriFieldTypeString, alias: OMS CREW ZONES, SQL Type: sqlTypeOther, length: 2, nullable: true, editable: true)
- GANGED (type: esriFieldTypeString, alias: GANGED, SQL Type: sqlTypeOther, length: 50, nullable: true, editable: true, Coded Values: [1: True], [2: False])
- GlobalID (type: esriFieldTypeGlobalID, alias: GlobalID, SQL Type: sqlTypeOther, length: 38, nullable: false, editable: false)
- CreationDate (type: esriFieldTypeDate, alias: CreationDate, SQL Type: sqlTypeOther, length: 8, nullable: true, editable: false)
- Creator (type: esriFieldTypeString, alias: Creator, SQL Type: sqlTypeOther, length: 128, nullable: true, editable: false)
- EditDate (type: esriFieldTypeDate, alias: EditDate, SQL Type: sqlTypeOther, length: 8, nullable: true, editable: false)
- Editor (type: esriFieldTypeString, alias: Editor, SQL Type: sqlTypeOther, length: 128, nullable: true, editable: false)
Types:
ID: 1
Name: Line Fuse
Domains:
- Field Name: ENABLED
Inherited
- Field Name: OPERATIONVOLTAGE
Inherited
- Field Name: NORMALPOSITION_A
Inherited
- Field Name: NORMALPOSITION_B
Inherited
- Field Name: NORMALPOSITION_C
Inherited
- Field Name: PHASEDESIGNATION
Inherited
- Field Name: NOMINALVOLTAGE
Inherited
- Field Name: TEMPFUSESIZE
Inherited
- Field Name: LINKTYPE
Inherited
- Field Name: LINKRATING
Inherited
- Field Name: GANGED
Inherited
Templates:
Name: Line Fuse
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- NORMALPOSITION_A: 1
- NORMALPOSITION_B: 1
- ENABLED: 1
- SUBTYPECD: 1
- MAXCONTINUOUSCURRENT: 200
- NORMALPOSITION_C: 1
- NOMINALVOLTAGE: 270
- LINKTYPE: K
ID: 2
Name: UG Fuse
Domains:
- Field Name: ENABLED
Inherited
- Field Name: OPERATIONVOLTAGE
Inherited
- Field Name: NORMALPOSITION_A
Inherited
- Field Name: NORMALPOSITION_B
Inherited
- Field Name: NORMALPOSITION_C
Inherited
- Field Name: PHASEDESIGNATION
Inherited
- Field Name: NOMINALVOLTAGE
Inherited
- Field Name: TEMPFUSESIZE
Inherited
- Field Name: LINKTYPE
Inherited
- Field Name: LINKRATING
Coded Values:[1: 65], [2: 80], [3: 100], More
- Field Name: GANGED
Inherited
Templates:
Name: UG Fuse
Description:
Drawing Tool: esriFeatureEditToolPoint
Prototype:
Attributes:
- NORMALPOSITION_A: 1
- NORMALPOSITION_B: 1
- ENABLED: 1
- SUBTYPECD: 2
- MAXCONTINUOUSCURRENT: 200
- NORMALPOSITION_C: 1
- NOMINALVOLTAGE: 270
- LINKTYPE: K
Is Data Versioned: false
Has Contingent Values: false
Supports Rollback On Failure Parameter: true
Last Edit Date: 6/2/2026 5:57:28 PM
Schema Last Edit Date: 6/2/2026 5:56:49 PM
Data Last Edit Date: 6/23/2026 2:48:05 PM
Supported Operations:
Query
Query Pivot
Query Top Features
Query Analytic
Query Bins
Add Features
Update Features
Delete Features
Apply Edits
Calculate
Generate Renderer
Validate SQL
Get Estimates
ConvertFormat